- Vysis FISH
- Abbott REAL-TIME PCR
- Ordering Information
Product Name | Unit Size | Order Number | GTIN |
Leading Science: RT-PCR detection of Zika virus RNA in serum, plasma, whole blood (EDTA), and urine specimens (whole blood and urine collected alongside a patient-matched serum or plasma specimen) with excellent analytical accuracy.
Enabling Solutions: Full specimen extraction to amplification with the m2000 system enables reduced hands-on time vs. other nucleic acid testing options.
Trusted Partner: Ensuring access to this important test to meet a public health need, from a proven and dedicated molecular testing source.
Intended Use: The Abbott RealTime ZIKA assay is an in vitro reverse transcription-polymerase chain reaction (RT-PCR) assay for the qualitative detection of RNA from the Zika virus in serum, EDTA plasma, whole blood (EDTA), and urine (whole blood and urine collected alongside a patient-matched serum or plasma specimen) from individuals meeting CDC Zika virus clinical criteria (e.g., clinical signs and symptoms associated with Zika virus infection) and/or CDC Zika virus epidemiological criteria (e.g., history of residence in or travel to a geographic region with active Zika virus transmission at the time of travel, or other epidemiologic criteria for which Zika virus testing may be indicated), by laboratories in the United States that are certified under the Clinical Laboratory Improvement Amendments of 1988 (CLIA), 42 U.S.C. §263a, to perform high complexity tests, or by similarly qualified non-U.S. laboratories.
Specimens are tested using the m2000sp for automated specimen processing and the m2000rt for amplification and detection.
Results are for the identification of Zika virus RNA. Zika virus RNA is generally detectable in serum, plasma, whole blood, and urine during the acute phase of infection and up to 14 days following onset of symptoms, if present. Positive results are indicative of current infection. Laboratories are required to report all positive results to the appropriate public health authorities.
Negative results do not preclude Zika virus infection and should not be used as the sole basis for patient management decisions. Negative results must be combined with clinical observations, patient history, and epidemiological information.
The Abbott RealTime ZIKA assay is intended for use by trained clinical laboratory personnel specifically instructed and trained in the techniques of nucleic acid amplification and in vitro diagnostic procedures. This assay is only for use under the Food and Drug Administration’s Emergency Use Authorization.
For In Vitro Diagnostic Use. For use under an Emergency Use Authorization (EUA) only.
1. Centers for Disease Control and Prevention. All countries & territories with active Zika virus transmission. Available at wwwnc.cdc.gov/travel/page/world-map-areas-with-zika. Accessed September 29, 2016
For Use Under An Emergency Use Authorization Only.
CAUTION: United States federal law restricts this device to sale and distribution to or on the order of a physician or to a clinical laboratory; and use is restricted to, by or on the order of a physician.
To learn more about RealTime ZIKA please visit: https://www.molecular.abbott/us/en/products/infectious-disease/realtime-zika
To access Fact Sheet for Patients please visit: https://www.molecular.abbott/sal/5-Abbott-Zika---FS-Patients-Final.pdf
To access Fact Sheet for Healthcare Providers please visit: https://www.molecular.abbott/sal/4-Abbott-Zika---FS-HCP-Final.pdf
Assay Specifications | |
Instrumentation | Extraction: m2000sp Amplification and Detection: m2000rt |
Technology | RealTime PCR |
Sample Type | Serum, EDTA plasma, whole blood (EDTA) and urine (whole blood and urine when collected alongside a patient-matched serum or plasma specimen) |
Input Volume | 0.5mL |
Limit of Detection (LOD) | 30 copies/mL (serum) 40 copies/mL (plasma) 40 copies/mL (urine) 120 copies/mL (whole blood) |
Internal Control | Processed with each sample |
Product | List Number | GTIN | Configuration |
Abbott RealTime Zika Amplification Kit | 09N27-090 | 00884999046771 | 96 assay (4 x 24) |
Abbott RealTime Zika Control Kit | 09N27-080 | 00884999046757 | 8 vials negative control 8 vials positive control |
Abbott RealTime Zika Combined Application CD-ROM |
09N27 | n/a | One CD-ROM |
Links which take you out of Abbott worldwide websites are not under the control of Abbott, and Abbott is not responsible for the contents of any such site or any further links from such site. Abbott is providing these links to you only as a convenience, and the inclusion of any link does not imply endorsement of the linked site by Abbott. The website that you have requested also may not be optimised for your screen size.
Please be aware that the website you have requested is intended for the residents of a particular country or countries, as noted on that site. As a result, the site may contain information on pharmaceuticals, medical devices and other products or uses of those products that are not approved in other countries or regions.